€748.54
pcs
Item description
Advantages:
•2 additional limit switches,
•Torque cut-off,
•Variable voltage (DC or AC),
•Manual override,
•Heater integrated in actuator housing,
•Construction according to DIN 3202-M3 and DVGW certified (PN 5 / MOP 5) for G 1/2" - G 2"


Ball valve


Materials:
Body: nickel-plated brass, ball: hard chromium plated brass, seals: PTFE / FKM

Temperature range:
-20°C up to max. +160°C (G 2-1/2" - G 3": max. +120°C), Gas: -20°C to max. +60°C)

Media:
Water, compressed air, vacuum (max. -0.9 bar), oils, fuels, heating oil, solvents, colours, paints, weak acids and alkalis

Rotary actuator


Description:
Electrical rotary actuator with optical position indicator, manual emergency operation and switch room heating Two additional limit switches are installed for further control requirements. An electronic torque limiting unit prevents damage in the event of overload. The manual emergency operation can be done without dismantling the external cladding. Do not use upside down!

Materials:
Body: PA 6

Temperature range:
-20 to +70 °C

Voltage:
24 - 240 V AC/DC, (drives can be operated with direct or alternating voltage)

Protection class:
IP 67

Power-on time:
75%

Optional:
Regulating time 140 sec. (only for drive size 2 & 3) -140, "Battery Safety Return" for emergency closing NC (default configuration) or emergency opening NO (conversion with a jumper) when there is a power failure -BSR, Positioning system 0 - 10 V or 4 - 20 mA (conversion with a jumper), precision: 3%, linearity: 2%, hysteresis: 3%, switch position NC or NO (conversion with a jumper) -DPS

Warning:
In case of high media temperatures, the actuator must be cooled if necessary!
Properties
Ver­sion Reg­u­lat­ing time 140 sec­onds.
Volt­age [V] 85 to 240 V (AC/DC)
Thread G 1/2"
DN [mm] 15
In­stal­la­tion length ball valve [mm] 75
PN [bar] -0,9 to 40
Reg­u­lat­ing time [s] 140
Spare dri­ves ELI 230-​2-140
Media tem­per­a­ture [°C] -20 to +160
Further information on KH12ELI230-140
Weight 2,2 kg / pcs
Customs duty number 84818081
Documents

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available