CMMP-AS-C10-11A-P3-M0 (1622904) motor controller

OT-FESTO037953

Exemplary representation: CMMP-AS-C2-3A-M0 (1622901)   &   CMMP-AS-C5-11A-P3-M0 (1622903)   &   CMMP-AS-C10-11A-P3-M0 (1622904)
3197,13€ incl. VAT
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Fastening type on connection plate,
Permanently screwed
Product weight [g] 3.800
Display Seven segment display
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directive,
acc. to EU Machine Directive,
acc. to EU Low voltage Directive,
acc. to EU-RoHS Directive
Bearing temperature [°C] -25 to 70
ambient temperature [°C] 0 to 40
Relative humidity 0 - 90 %
Protection category IP10,
IP20
Degree of contamination 2
Material information LABS containing materials included,
RoHs compliant
Phase nominal operating voltage 3-phase
Nominal operating voltage AC [V] 400
Permitted voltage oscillations ± 10 %
Network frequency [Hz] 50 to 60
Nominal current [A] 11
Network filter integrated
Max. intermediate circuit voltage DC [V] 560
Braking resistance [Ohm] 68
Impulse power braking resistance [kVA] 8,5
Nominal voltage logic supply DC [V] 24
Permitted range logic voltage ± 20 %
Power input logic supply without parking brake [A] 1,00
Output voltage range AC 3x 0 - 360 V
Nominal output current [A] 10,0
Nominal current per phase, effective [A] 10,0
Peak current per phase, effective [A] 20
Max. peak current duration [s] 5
Nominal performance controller [VA] 6.000
Peak performance [VA] 12.000
Output frequency [Hz] 0 to 1000
Parameterising interface USB,
Ethernet,
Parameterising and commissioning
Fieldbus coupling CANopen,
Modbus/TCP
Communication profile DS301/DSP402
Process coupling I/O coupling,
for 256 mobile sets
Max. fieldbus transfer rate [Mbit/s] 1
Bus connector Sub-D,
9 pin,
Plug
Encoder output interface, properties Resolution 16384 ppr
Encoder output interface, function Actual value feedback via encoder signals for speed control mode,
Target value for downstream switched slave actuator
Encoder input interface, properties HIPERFACE,
RS422,
SINCOS,
EnDat,
3 phasige Encodersignale
Encoder input interface, function In synchronous mode as a speed preset of the slave actuator,
Encoder signal target speed value
Quantity digital logic inputs 10
Properties logic inputs Freely configurable,
Galvanically separated
Work area logic input [V] 8 to 30
Quantity digital logic outputs 24 V DC 5
Properties digital logic outputs Galvanically separated,
Partially freely configurable
Max. current digital logic outputs [mA] 100
Quantity analogue target value inputs 2
Properties target value inputs Differential inputs,
Configurable for speed,
Configurable for current
Work area target value input ± 10 V
Impedance target value input [kOhm] 20
Quantity analogue monitor outputs 2
Work area monitor outputs ± 10 V
Resolution monitor outputs [Bit] 9
Properties monitor outputs Short circuit proof
Certified awarding point 01/205/5162.02/19,
TÜV Rheinland
Safety function Safe switched off torque (STO),
Safe stop 1 (SS1)
Safety Integrity Level (SIL) Safe switched off torque (STO) / SIL 3 / SILCL 3
Performance Level (PL) Safe switched off torque (STO) / category 4 performance level e
Diagnose degree of coverage [%] 97
SFF Safe Failure Fraction [%] 99,17
Hardware error tolerance 1
Proof test interval [A] 20
OT-FESTO037953
{{ $t('shop.all.gewicht') }} 3.800 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 85044085
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}

Accessories

{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.